Fire safety

Fire safety was not generally a consideration when art deco houses were being built.

Fire safety was not generally a consideration for the design and construction of art deco houses and the dry timber they contain can burn readily. Plasterboard linings reduce the risk of fire spread but furnishings also present a significant fire load.

Fire safety features

When any renovation work is being carried out, this must include consideration of fire safety. This may include:

  • installing smoke alarms (this is mandatory)
  • installing heat detectors
  • consideration of a domestic fire sprinkler system.

Chimneys will also need to be assessed for fire safety if the fireplaces they serve are to be used for heating.

Back to top

Smoke alarms

Smoke alarms detect the smoke particles from a fire. There are two common types:

  • A photo-electric smoke alarm, which uses a beam of light and a light sensor. When smoke particles affect the amount of light reaching the sensor, an alarm will sound.
  • An ionisation smoke alarm, which monitors the ions (electrically charged particles). When the electrical balance of the air is altered by the smoke particles, the alarm will sound.

To be effective, an installed smoke alarm must be operating properly, audible through closed doors and able to detect smoke from all types of fires.
Domestic smoke alarms are typically battery-powered and provide good warning of the presence of smoke and fire as long as batteries are replaced regularly. Mains-connected systems (with battery back-up in the event of a power failure) are also available.
Smoke alarms are available with extra loud alarms, flashing lights or vibrating devices for people with hearing loss.

Back to top

Domestic smoke alarm requirements

The New Zealand Building Code requires that all existing houses undergoing alteration (as well as new houses) have smoke alarms installed. Domestic smoke alarms must be Type 1, which has:

  • a hush button so the alarm can be cleared without shutting off power (i.e. by removing the battery)
  • a test button.

 

Back to top

Installation

Smoke alarms should be installed:

  • on (preferably) or near the ceiling
  • on the escape route of each floor level of a household unit
  • in every sleeping space or within 3.0 m of a sleeping space door
  • in sleep-outs.

If a smoke alarm must be located on a wall, install it 100 mm from the ceiling and 600 mm from a corner to avoid dead air pockets.
Do not install smoke alarms:

  • in a kitchen, garage or bathroom unless specifically designed for these spaces – heat detectors can be installed in these spaces instead
  • close to a heater flue or an extract fan.

Back to top

Maintenance of smoke alarms

Maintenance of smoke alarms includes:

  • monthly testing of the alarm test facility
  • annual, in situ cleaning with a vacuum cleaner (no disassembly required)
  • replacement every 10 years.

Back to top

Domestic sprinklers

Sprinklers provide the most effective protection against fire damage, and systems suitable for domestic installations are available. If a fire starts, the sprinkler heads immediately above the fire will discharge water.
The most common domestic fire sprinkler systems:

  • use a glass bulb, heat-sensitive element
  • activate at about 68°C
  • have a flat and wide spray pattern with small and medium droplet sizes
  • have sprinkler heads that may be concealed, flush-mounted, side-wall or pendant type
  • require a 20 mm diameter pipe connection.

If a fire develops, not all sprinkler heads will operate, but only those closest to the fire – 65% of fires are controlled by a single sprinkler head, and 95% are controlled by five sprinkler heads or less.
When a sprinkler head is set off, the fire brigade is also called.

Back to top

Installation and maintenance

The design and installation of a domestic sprinkler system must be carried out by a qualified practitioner with independent inspection and certification.

Maintenance and testing should be in accordance with the relevant standards and in accordance with the manufacturer’s instructions.

Back to top

Heaters and other appliances

All appliances that burn gas, oil, solid fuel or any other combustible material must be installed to ensure that:

  • the combustion process does not raise the temperature of any adjacent building element to a level where its performance is affected
  • the accumulation of combustion gases within the building is avoided.